| MOQ: | 1 Sets |
| Price: | 10000 USD |
| Delivery Period: | 2 months |
| Payment Method: | L/C,T/T |
| Supply Capacity: | 200 sets / days |
What Is A Reactor In Water Treatment
A reactor in water treatment is a tank or vessel where water is cleaned by a controlled biological, chemical, or physical reaction rather than simple storage. It is where contaminants are converted, precipitated, or broken down so the effluent meets its target.
The difference from a plain tank is intent: a treatment reactor is sized and instrumented for a reaction rate, not just holdup. The reactor type follows the contaminant and the treatment goal.
What Is a Reactor in Water Treatment?
It is a containment volume in which a treatment reaction proceeds under controlled residence time, mixing, temperature, and dosing. Examples include biological reactors for organic removal, equalization reactors for flow and load smoothing, and chemical reactors for precipitation or oxidation.
How Does a Water-Treatment Reactor Work?
Water enters with its contaminant load. In a biological reactor, microbes convert organics; in a chemical reactor, a dosed reagent precipitates or oxidizes the pollutant; in an equalization reactor, mixing smooths peaks before downstream units. Residence time is the key design variable.
Key Types
Applications
Municipal sewage, industrial wastewater, landfill and incineration leachate, and agricultural wastewater all use treatment reactors. The duty sets the size, material, and corrosion allowance.
Technical Considerations
How to Select the Right Reactor
Water-Treatment Reactor Comparison
| Type | Removes | Mechanism | Typical material |
|---|---|---|---|
| Biological | Dissolved organics | Microbial conversion | Steel / GFS |
| Anaerobic digester | Sludge organics | Biogas conversion | Steel / GFS |
| Equalization | Load peaks | Mixing buffer | Steel / GFS |
| Chemical | Metals, P, color | Precipitation/oxidation | Steel / lined |
A water-treatment reactor is defined by the reaction it runs, not its shape. Pick the type by contaminant, size it by residence time and load, and verify material, corrosion allowance, and code for the duty.
Project Case Study
| Project Information | Details |
|---|---|
| Project | Sichuan Aquaculture Wastewater Treatment Project |
| Location | Sichuan, China |
| Industry | Aquaculture wastewater |
| Application | Wastewater reaction and treatment |
| Product | Welded steel treatment tanks |
| Capacity / Quantity | Phi 6 x 16.5 m (h) x1; phi 7.6 x 16.5 m (h) x1 |
| Material | Carbon steel (welded) |
| Standards | Welded tank practice |
| Project Status | Delivered |
Project Background
A Sichuan site needed reactors/tanks to treat aquaculture wastewater before discharge or reuse.
Project Requirements
Two welded steel tanks, phi 6 x 16.5 m and phi 7.6 x 16.5 m, for continuous aquaculture-wastewater treatment.
Technical Challenges
The tanks had to provide stable residence time for the treatment reaction while withstanding the wastewater environment over the service life.
Solution
Two welded steel tanks were supplied at the specified dimensions to give the required treatment volume.
Implementation
Fabrication and delivery followed the project schedule with the tanks integrated into the treatment line.
Project Outcome
Tanks delivered for aquaculture wastewater treatment. Verified: size, medium, and application as listed.
About Shijiazhuang Zhengzhong Technology Co., Ltd. (Center Enamel)
Shijiazhuang Zhengzhong Technology Co., Ltd. (Center Enamel) supplies engineered tanks and reactors for water and wastewater treatment, with application experience across municipal, industrial, leachate, and agricultural wastewater duties.
The company designs treatment volumes for residence time and load, selecting welded steel or glass-fused-to-steel construction with corrosion allowance suited to the wastewater.
Frequently Asked Questions (FAQ)
What is a reactor in water treatment?
A tank where a biological, chemical, or physical reaction cleans water, sized by residence time and reaction rate rather than just storage.
What types are used?
Biological (activated sludge, MBBR), anaerobic digestion, equalization, and chemical precipitation or oxidation reactors.
What material is used?
Welded steel or glass-fused-to-steel with a corrosion allowance of 2.5-3 mm for aggressive wastewater.
How is size determined?
By residence time and contaminant load, not only total volume.
What standards apply?
GB50341/GB50128 in China, AWWA or EN for export, with documented inspection.
What do I send for a quote?
Flow, contaminant profile, target effluent, temperature, and required code or certification.