Products
PRODUCTS DETAILS
Home > Products >
What Is A Reactor In Water Treatment

What Is A Reactor In Water Treatment

MOQ: 1 Sets
Price: 10000 USD
Delivery Period: 2 months
Payment Method: L/C,T/T
Supply Capacity: 200 sets / days
Detail Information
Place of Origin
China
Brand Name
Center Enamel
Certification
ASME,ISO 9001,CE, NSF/ANSI 61, WRAS, ISO 28765, LFGB, BSCI, ISO 45001
Material:
Stainless Steel, Carbon Steel
Size:
Customized
Design Pressure:
0.1-10 Mpa
Applications:
Chemical, Food Processing, Beverage Processing, Brewing, Metallurgy, Oil Refining, Pharmaceuticals
Highlight:

water treatment reactor tank

,

stainless steel reactor tank

,

water treatment stainless steel reactor

Product Description

What Is A Reactor In Water Treatment

A reactor in water treatment is a tank or vessel where water is cleaned by a controlled biological, chemical, or physical reaction rather than simple storage. It is where contaminants are converted, precipitated, or broken down so the effluent meets its target.

The difference from a plain tank is intent: a treatment reactor is sized and instrumented for a reaction rate, not just holdup. The reactor type follows the contaminant and the treatment goal.

What Is a Reactor in Water Treatment?

It is a containment volume in which a treatment reaction proceeds under controlled residence time, mixing, temperature, and dosing. Examples include biological reactors for organic removal, equalization reactors for flow and load smoothing, and chemical reactors for precipitation or oxidation.

How Does a Water-Treatment Reactor Work?

Water enters with its contaminant load. In a biological reactor, microbes convert organics; in a chemical reactor, a dosed reagent precipitates or oxidizes the pollutant; in an equalization reactor, mixing smooths peaks before downstream units. Residence time is the key design variable.

Key Types

  • Biological (activated sludge / MBBR): microbes remove dissolved organics.
  • Anaerobic digestion reactor: converts sludge and organic waste to biogas.
  • Equalization reactor: buffers flow and load before treatment.
  • Chemical precipitation/oxidation reactor: removes metals, phosphorus, or color.

Applications

Municipal sewage, industrial wastewater, landfill and incineration leachate, and agricultural wastewater all use treatment reactors. The duty sets the size, material, and corrosion allowance.

Technical Considerations

  • Residence time: sized to the reaction rate and load.
  • Material: welded steel or glass-fused-to-steel for corrosion and life.
  • Corrosion allowance: 2.5-3 mm for aggressive wastewater.
  • Code: GB50341/GB50128 for Chinese welded tanks; AWWA/EN for export.

How to Select the Right Reactor

  • Match the contaminant: biological for organics, chemical for metals and phosphorus.
  • Size by load: residence time, not just volume, drives the design.
  • Verify the code: confirm GB or the export standard with inspection.

Water-Treatment Reactor Comparison

Type Removes Mechanism Typical material
Biological Dissolved organics Microbial conversion Steel / GFS
Anaerobic digester Sludge organics Biogas conversion Steel / GFS
Equalization Load peaks Mixing buffer Steel / GFS
Chemical Metals, P, color Precipitation/oxidation Steel / lined

A water-treatment reactor is defined by the reaction it runs, not its shape. Pick the type by contaminant, size it by residence time and load, and verify material, corrosion allowance, and code for the duty.

Project Case Study

Project Information Details
Project Sichuan Aquaculture Wastewater Treatment Project
Location Sichuan, China
Industry Aquaculture wastewater
Application Wastewater reaction and treatment
Product Welded steel treatment tanks
Capacity / Quantity Phi 6 x 16.5 m (h) x1; phi 7.6 x 16.5 m (h) x1
Material Carbon steel (welded)
Standards Welded tank practice
Project Status Delivered

Project Background

A Sichuan site needed reactors/tanks to treat aquaculture wastewater before discharge or reuse.

Project Requirements

Two welded steel tanks, phi 6 x 16.5 m and phi 7.6 x 16.5 m, for continuous aquaculture-wastewater treatment.

Technical Challenges

The tanks had to provide stable residence time for the treatment reaction while withstanding the wastewater environment over the service life.

Solution

Two welded steel tanks were supplied at the specified dimensions to give the required treatment volume.

Implementation

Fabrication and delivery followed the project schedule with the tanks integrated into the treatment line.

Project Outcome

Tanks delivered for aquaculture wastewater treatment. Verified: size, medium, and application as listed.

About Shijiazhuang Zhengzhong Technology Co., Ltd. (Center Enamel)

Shijiazhuang Zhengzhong Technology Co., Ltd. (Center Enamel) supplies engineered tanks and reactors for water and wastewater treatment, with application experience across municipal, industrial, leachate, and agricultural wastewater duties.

The company designs treatment volumes for residence time and load, selecting welded steel or glass-fused-to-steel construction with corrosion allowance suited to the wastewater.

  • Application expertise: municipal, industrial, leachate, and agricultural wastewater.
  • Qualifications: Special Equipment Manufacturing License, Class I/II pressure vessels.
  • Certifications: ISO 28765, NSF/ANSI 61, WRAS, ASME, ISO 9001.

Frequently Asked Questions (FAQ)

What is a reactor in water treatment?

A tank where a biological, chemical, or physical reaction cleans water, sized by residence time and reaction rate rather than just storage.

What types are used?

Biological (activated sludge, MBBR), anaerobic digestion, equalization, and chemical precipitation or oxidation reactors.

What material is used?

Welded steel or glass-fused-to-steel with a corrosion allowance of 2.5-3 mm for aggressive wastewater.

How is size determined?

By residence time and contaminant load, not only total volume.

What standards apply?

GB50341/GB50128 in China, AWWA or EN for export, with documented inspection.

What do I send for a quote?

Flow, contaminant profile, target effluent, temperature, and required code or certification.